NOTE: The following instructions are for G-405. Other fixtures are similar. Step 1: Remove consumables; nozzle, retaining head and neck insulator (with the exception of TOUGH GUN I.C.E.® components).Install the gauge point into the neck. Step 2: Slide the neck completely into the datum block, aligning keys on the neck to the keyway in the […]
read more...
NOTE: There is a protective ring that must be rotated to expose the neck set screw. Step 1: Using a 5 mm Allen wrench, loosen the screw 1/4 turn to remove the neck.Pull the neck directly out of the connector cone assembly. Step 2: Insert the replacement neck into the gun housing, ensuring the key […]
read more...
Unicable Repair Kit Part #513-7 Remove the liner from the MIG gun.Remove the screws from the base of the terminal housing. Remove the terminal housing and move the handle backDisconnect the cable leads from the Euro butt connectors.Move the Euro hand nut and spacer out of the way. Be careful not to strip the lead […]
read more...
Tregaskiss I.C.E. components will come assembled on your MIG gun. You will need to remove the Tregaskiss I.C.E. neck assembly to install it on the robot. Step 1: Remove front-end consumables. Disconnect both water lines at the Quick Connect coupler. Step 2: Loosen neck bolt. Remove Tregaskiss I.C.E. neck assembly Step 3: Insert the connector […]